Dewatering works for the amplification of the sewage treatment plant “IDA-Giubiasco” (TI, CH)


PURPOSES
CLIENT
GEOLOG.CH, 2024.
WHAT WE DID
We enabled realistic and dependable assessment of dewatering needs (pumping rates volumes) to model and cross-compared various scenarios using a working 3D hydrogeological numerical model approach. A solution combining a pumping system, such as dewatering pumps, at the bottom of the excavation pit and “sheet piles” around the excavation pit has been studied.